Foto del docente

Luca Cristofolini

Full Professor

Department of Industrial Engineering

Academic discipline: IBIO-01/A Bioengineering

Publications

Viceconti M.; Affatato S.; Baleani M.; Bordini B.; Cristofolini L.; Taddei F., Pre-clinical validation of joint prostheses: a systematic approach, «JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS», 2009, 2, pp. 120 - 127 [Scientific article]

Cristofolini L.; Juszczyk M.; Taddei F.; Viceconti M., Strain distribution in the proximal human femoral metaphysis, «PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS. PART H, JOURNAL OF ENGINEERING IN MEDICINE», 2009, 223, pp. 273 - 288 [Scientific article]

Cristofolini L.; Juszczyk M.; Taddei F.; Field R.E.; Rushton N.; Viceconti M., Stress-shielding and stress-concentration of contemporary epiphyseal hip prostheses, «PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS. PART H, JOURNAL OF ENGINEERING IN MEDICINE», 2009, 223, pp. 27 - 44 [Scientific article]

Benedikt Helgason; Taddei F.; Halldór Pálsson; Schileo E.; Cristofolini L.; Viceconti M.; Sigurdur Brynjólfsson, A modified method for assigning material properties to FE models of bones, «MEDICAL ENGINEERING & PHYSICS», 2008, 30, pp. 444 - 453 [Scientific article]

Affatato S.; Cristofolini L.; Leardini W.; Erani P.; Zavalloni M.; Tigani D.; Viceconti M., A new method of in vitro wear assessment of the UHMWPE tibial insert in total knee replacement, «ARTIFICIAL ORGANS», 2008, 32, pp. 942 - 948 [Scientific article]

Conti G.; Cristofolini L.; Juszczyk M.; Malandrino A.; Viceconti M., Anatomical axes for the human tibia and fibula: assessment of two reference systems, «JOURNAL OF BIOMECHANICS», 2008, 41, pp. s407 - s407 [Scientific article]

Cristofolini L.; Erani P.; Savigni P.; Grupp T.; Thies O. ;Viceconti M., Authors’ reply to the Letter to the Editor: “Increased long-term failure risk associated with excessively thin cement mantle in cemented hip arthroplasty. A comparative in vitro study” (Clinical Biomechanics 22 (2007) 410–421), «CLINICAL BIOMECHANICS», 2008, 23(4), pp. 501 - 503 [Comment or similar]

Varini E.; Cristofolini L.; Traina F.; Viceconti M.; Toni A., Can the rasp be used to predict intra-operatively the primary stability that can be achieved by press-fitting the stem in cementless hip arthroplasty?, «CLINICAL BIOMECHANICS», 2008, 23, pp. 408 - 414 [Scientific article]

Conti G.; Cristofolini L.;Juszczy M.; Leardini A.;Viceconti M., Comparison of three standard anatomical reference frames for the tibia-fibula complex, «JOURNAL OF BIOMECHANICS», 2008, 41, pp. 3384 - 3389 [Scientific article]

Tassani S.; Perilli E.; Baruffaldi F.; Cristofolini L.; Viceconti M., Differences in trabecular anisotropy between osteoarthritic and normal bone, «JOURNAL OF BIOMECHANICS», 2008, 41(s1), pp. 46 - 46 [Abstract]

Gray H.A.; Taddei F.; Zavatsky A.B.; Cristofolini L.; Gill H. S., Experimental validation of a finite element model of a human cadaveric tibia, «JOURNAL OF BIOMECHANICAL ENGINEERING», 2008, 130(3), pp. 031016 - 031016 [Scientific article]

Schileo E.; Taddei F.; Martelli S.; Cristofolini L.; Moindreau M.; Viceconti M., FE probabilistic approach to define the clinical indications of a new proximal epiphyseal replacement, «JOURNAL OF BIOMECHANICS», 2008, 41(s1), pp. 35 - 35 [Abstract]

Bialoblocka-Juszczyk E.; Baleani M.;Cristofolini L.; Viceconti M., Fracture properties of an acrylic bone cement, «ACTA OF BIOENGINEERING AND BIOMECHANICS», 2008, 10, pp. 21 - 26 [Scientific article]

Tassani S.; Baruffaldi F.; Öhman C.; Baleani M.; Cristofolini L.; Viceconti M., Global to local analysis of anisotropy in osteoarthritic bone, «JOURNAL OF BIOMECHANICS», 2008, 41(s1), pp. 338 - 338 [Abstract]

Cristofolini L.; Affatato S.; Erani P.; Leardini W.; Tigani D.; Viceconti M., Long-term implant-bone fixation of the femoral component in total knee replacement, «PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS. PART H, JOURNAL OF ENGINEERING IN MEDICINE», 2008, 222(3), pp. 319 - 331 [Scientific article]