Foto del docente

Luca Cristofolini

Full Professor

Department of Industrial Engineering

Academic discipline: ING-IND/34 Industrial Bioengineering

Publications

L. Cristofolini; E. Schileo; M.Juszczyk; F. Taddei; S. Martelli; M. Viceconti|, Mechanical testing of bones: the positive synergy of finite-element models and in vitro experiments, «PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES A: MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES», 2010, 368, pp. 2725 - 2763 [Scientific article]

Harman M.; Danesi V.; Cristofolini L.; Stea S.; Beraudi A.; Tersi L.; Viceconti M., Re-Use of Explanted Osteosynthesis Devices: Cleaning and Inspection Protocol for Assessing Device Integrity, in: 56th Annual Meeting of the Orthopaedic Research Society, NEW ORLEANS, LOUISIANA, s.n, 2010, pp. 78 - 79 (atti di: ORS 2010, NEW ORLEANS, LOUISIANA, March 6-9, 2010) [Abstract]

L. Cristofolini; G. Conti; M. Juszczyk; S.Cremonini; S. Van Sint Jan; M. Viceconti;, Structural behaviour and strain distribution of the long bones of the human lower limbs, «JOURNAL OF BIOMECHANICS», 2010, 43, pp. 826 - 835 [Scientific article]

H. Gray; A. Zavatsky; L. Cristofolini; and H. Gill, The relationship between the accuracy of results and the number of material properties used in finite element analysis of the human tibia, «JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME», 2010, 92-B, pp. 278 - 279 [Scientific article]

Cristofolini L.; Viceconti M., Comments on: “In vitro analysis of Exeter stem torsional stability” by Bell CG, Weinrauch P, Pearcy M, Crawford R Published on J Arthroplasty. 2007 Oct;22(7):1024-30, «THE JOURNAL OF ARTHROPLASTY», 2009, 24, pp. 657 - 659 [Comment or similar]

Bialoblocka-Juszczyk E; Baleani M; Cristofolini L; Viceconti M, Effect of stem preheating on the fatigue behaviour of bone cement around hip prostheses, «PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS. PART H, JOURNAL OF ENGINEERING IN MEDICINE», 2009, 223, pp. 637 - 641 [Scientific article]

Gray H; Zavatsky A; Cristofolini L; Murray D; Gill H S, Experimentally validated finite element model of a human tibia with a unicompartmental knee replacement, in: , «JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME», 2009, 91-B, pp. 30 - 31 (atti di: EFORT - European Federation of National Associations of Orthopaedics and Traumatology (8th Congress), Florence, 11–15 May 2007) [Abstract]

Cristofolini L; Affatato S; Erani P; Tigani D; Viceconti M, Implant fixation in knee replacement: preliminary in vitro comparison of ceramic and metal cemented femoral components, «THE KNEE», 2009, 16, pp. 101 - 108 [Scientific article]

Grupp T M; Yue J J; Garcia R; Cocchi P; Schilling L; Cristofolini L; Blomer W, In-vitro flexibility in the lumbar spine before and after total disc arthroplasty, «JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME», 2009, 91-B, pp. 148 - 149 [Scientific article]

Traina F.; Tassinari E.; De Fine M.; Biondi F.; Cristofolini L.; Toni A., Outcome of hybrid stem fixation in osteoporotic female patients. A minimum 5-year follow-up study, «INTERNATIONAL ORTHOPAEDICS», 2009, 33(6), pp. 1489 - 1494 [Scientific article]

Viceconti M.; Affatato S.; Baleani M.; Bordini B.; Cristofolini L.; Taddei F., Pre-clinical validation of joint prostheses: a systematic approach, «JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS», 2009, 2, pp. 120 - 127 [Scientific article]

Cristofolini L.; Juszczyk M.; Taddei F.; Viceconti M., Strain distribution in the proximal human femoral metaphysis, «PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS. PART H, JOURNAL OF ENGINEERING IN MEDICINE», 2009, 223, pp. 273 - 288 [Scientific article]

Cristofolini L.; Juszczyk M.; Taddei F.; Field R.E.; Rushton N.; Viceconti M., Stress-shielding and stress-concentration of contemporary epiphyseal hip prostheses, «PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS. PART H, JOURNAL OF ENGINEERING IN MEDICINE», 2009, 223, pp. 27 - 44 [Scientific article]

Benedikt Helgason; Taddei F.; Halldór Pálsson; Schileo E.; Cristofolini L.; Viceconti M.; Sigurdur Brynjólfsson, A modified method for assigning material properties to FE models of bones, «MEDICAL ENGINEERING & PHYSICS», 2008, 30, pp. 444 - 453 [Scientific article]

Affatato S.; Cristofolini L.; Leardini W.; Erani P.; Zavalloni M.; Tigani D.; Viceconti M., A new method of in vitro wear assessment of the UHMWPE tibial insert in total knee replacement, «ARTIFICIAL ORGANS», 2008, 32, pp. 942 - 948 [Scientific article]